Текущий выпуск Номер 4, 2025 Том 17

Все выпуски

Результаты поиска по 'digital filter':
Найдено статей: 5
  1. От редакции
    Компьютерные исследования и моделирование, 2024, т. 16, № 7, с. 1533-1538
    Editor’s note
    Computer Research and Modeling, 2024, v. 16, no. 7, pp. 1533-1538
  2. Аксенов К.В., Алексеев В.П.
    Фильтрация цифровых сигналов в режиме непрерывного поступления данных
    Компьютерные исследования и моделирование, 2012, т. 4, № 1, с. 55-61

    Cтатья посвящена выбору метода цифровой фильтрации сигнала при поступлении данных в режиме реального времени и использованию алгоритма фильтрации на основе быстрого вейвлет-преобразования в рамках специальной задачи.

    Aksyonov K.V., Alekseev V.P.
    Digital signals filtering in continuous entry data mode operation
    Computer Research and Modeling, 2012, v. 4, no. 1, pp. 55-61

    The article is dedicated to choose of method for digital signal filtering with continuous 'on-line' data entry and to use of filtration algorithm based on the fast wavelet transform for special problem.

    Просмотров за год: 6. Цитирований: 7 (РИНЦ).
  3. В работе предлагается подход, позволяющий организовать оперативный контроль за интенсивностью действия источника выбросов в атмосферу. Восстановление неизвестной интенсивности источника загрязнения атмосферы производится по измерениям концентрации примеси в отдельных стационарных точках. Для решения обратной задачи использовались методы шаговой регуляризации и последовательной функциональной аппроксимации. Решение представлено в форме цифрового фильтра в смысле Хэмминга. Описан алгоритм выбора регуляризирующего параметра r для метода функциональной аппроксимации. Работа продолжает исследования, представленные в [1,2].

    Chubatov A.A., Karmazin V.N.
    The stable estimation of intensity of atmospheric pollution source on the base of sequential function specification method
    Computer Research and Modeling, 2009, v. 1, no. 4, pp. 391-403

    The approach given in this work helps to organize the operative control over action intensity of pollution emissions in atmosphere. The approach allows to sequential estimate of unknown intensity of atmospheric pollution source on the base of concentration measurements of impurity in several stationary control points is offered in the work. The inverse problem was solved by means of the step-by-step regularization and the sequential function specification method. The solution is presented in the form of the digital filter in terms of Hamming. The fitting algorithm of regularization parameter r for function specification method is described.

    Просмотров за год: 2.
  4. Нестерова А.В., Денисова Н.В., Минин С.М., Анашбаев Ж.Ж., Усов В.Ю.
    Определение поправочных коэффициентов при количественной оценке костных патологических очагов методом гамма-эмиссионной томографии
    Компьютерные исследования и моделирование, 2025, т. 17, № 4, с. 677-696

    При обследовании методом однофотонной эмиссионной компьютерной томографии (ОФЭКТ) пациентам с заболеваниями костной системы вводится радиофармпрепарат (РФП), который специфическим образом накапливается в патологических очагах. Количественные оценки накопления РФП в очагах важны для определения стадии заболевания, прогнозирования его течения и разработки персонализированных терапевтических стратегий. Исследования точности количественных оценок обычно проводятся на основе клинических испытаний in vitro с использованием стандартизированного вещественного фантома NEMA IEC с шестью сферами, имитирующими патологические очаги разных размеров. Однако возможности проведения таких многопараметрических экспериментальных измерений ограничены из-за высокойстоимости и лучевой нагрузки на исследователей. В данной работе развит альтернативный подход на основе имитационного компьютерного моделирования in silico с использованием цифрового двойника фантома NEMA IEC. Компьютерные эксперименты могут проводиться без ограничений с разными сценариями. По аналогии с клиническими испытаниями в численном моделировании оценивался коэффициент восстановления (RCmax), равный отношению максимального значения полученного решения в очаге к его точной величине. Условия моделирования были ориентированы на параметры клинических обследований методом ОФЭКТ/КТ с 99mTc пациентов с заболеваниями и поражениями костной системы. Впервые выполнены исследования зависимости RCmax от величины отношения «очаг/фон» и влияния постфильтрации решения. В численных экспериментах были получены краевые артефакты на изображениях очагов, аналогичные тем, которые наблюдались при измерениях на реальном фантоме NEMA IEC и в клинической практике при обследовании пациентов. Краевые артефакты приводят к нестабильности поведения решения в итерационном процессе и к ошибкам в оценке накопления РФП в очагах. Показано, что постфильтрация снижает влияние этих артефактов, обеспечивая стабильное решение. Однако при этом существенно занижаются оценки решения в небольших очагах, поэтому предложено учитывать полученные в данной работе поправочные коэффициенты при количественной оценке активности в очагах диаметром менее 20 мм.

    Nesterova A.V., Denisova N.V., Minin S.M., Anashbaev Z.Z., Usov V.Y.
    Determination of post-reconstruction correction factors for quantitative assessment of pathological bone lesions using gamma emission tomography
    Computer Research and Modeling, 2025, v. 17, no. 4, pp. 677-696

    In single-photon emission computed tomography (SPECT), patients with bone disorders receive a radiopharmaceutical (RP) that accumulates selectively in pathological lesions. Accurate quantification of RP uptake plays a critical role in disease staging, prognosis, and the development of personalized treatment strategies. Traditionally, the accuracy of quantitative assessment is evaluated through in vitro clinical trials using the standardized physical NEMA IEC phantom, which contains six spheres simulating lesions of various sizes. However, such experiments are limited by high costs and radiation exposure to researchers. This study proposes an alternative in silico approach based on numerical simulation using a digital twin of the NEMA IEC phantom. The computational framework allows for extensive testing under varying conditions without physical constraints. Analogous to clinical protocols, we calculated the recovery coefficient (RCmax), defined as the ratio of the maximum activity in a lesion to its known true value. The simulation settings were tailored to clinical SPECT/CT protocols involving 99mTc for patients with bone-related diseases. For the first time, we systematically analyzed the impact of lesion-to-background ratios and post-reconstruction filtering on RCmax values. Numerical experiments revealed the presence of edge artifacts in reconstructed lesion images, consistent with those observed in both real NEMA IEC phantom studies and patient scans. These artifacts introduce instability into the iterative reconstruction process and lead to errors in activity quantification. Our results demonstrate that post-filtering helps suppress edge artifacts and stabilizes the solution. However, it also significantly underestimates activity in small lesions. To address this issue, we introduce post-reconstruction correction factors derived from our simulations to improve the accuracy of quantification in lesions smaller than 20 mm in diameter.

  5. Деев А.А., Кальщиков А.А.
    Когерентный приемопередатчик с постоянной задержкой для синхронной оптоволоконной сети
    Компьютерные исследования и моделирование, 2023, т. 15, № 1, с. 141-155

    В статье предлагается реализация когерентного приемопередатчика с постоянной задержкой и возможностью свободно варьируемой сетки тактовых частот, используемой для тактирования периферийных ЦАП и АЦП, задач синхронизации устройств и передачи данных. Выбор необходимой сетки тактовых частот напрямую влияет на скорость передачи данных в сети, однако позволяет гибко настроить сеть для передачи тактовых сигналов и генерации синхроимпульсов с субнаносекундной точностью на всех устройствах в сети. Предложен метод повышения точности синхронизации до десятых долей наносекунды за счет использования цифровых фазовых детекторов и системы фазовой автоподстройки частоты (ФАПЧ) на ведомом устройстве. Использование высокоскоростных волоконно-оптических линий связи (ВОЛС) для задач синхронизации шкал времени, позволяет параллельно синхронизации производить обмен командами управления и сигнальными данными. Для упрощения и удешевления устройств синхронной сети приемопередатчиков предлагается использовать тактовый сигнал, восстановленный из сериализованных данных, и прошедший фильтрацию фазовых шумов, для формирования в системе ФАПЧ тактовых сигналов периферийных устройств, таких как ЦАП и АЦП, а также сигналов гетеродина. Представлены результаты многократных тестов синхронизации в предложенной синхронной сети.

    Deev A.A., Kalshchikov A.A.
    Coherent constant delay transceiver for a synchronous fiber optic network
    Computer Research and Modeling, 2023, v. 15, no. 1, pp. 141-155

    This paper proposes the implementation of a coherent transceiver with a constant delay and the ability to select any clock frequency grid used for clocking peripheral DACs and ADCs, tasks of device synchronization and data transmission. The choice of the required clock frequency grid directly affects the data transfer rate in the network, however, it allows one to flexibly configure the network for the tasks of transmitting clock signals and subnanosecond generation of sync signals on all devices in the network. A method for increasing the synchronization accuracy to tenths of nanoseconds by using digital phase detectors and a Phase Locked Loop (PLL) system on the slave device is proposed. The use of high-speed fiber-optic communication lines (FOCL) for synchronization tasks allows simultaneously exchanging control commands and signaling data. To simplify and reduce the cost of devices of a synchronous network of transceivers, it is proposed to use a clock signal restored from a data transmission line to filter phase noise and form a frequency grid in the PLL system for heterodyne signals and clock peripheral devices, including DAC and ADC. The results of multiple synchronization tests in the proposed synchronous network are presented.

Журнал индексируется в Scopus

Полнотекстовая версия журнала доступна также на сайте научной электронной библиотеки eLIBRARY.RU

Журнал включен в базу данных Russian Science Citation Index (RSCI) на платформе Web of Science

Международная Междисциплинарная Конференция "Математика. Компьютер. Образование"

Международная Междисциплинарная Конференция МАТЕМАТИКА. КОМПЬЮТЕР. ОБРАЗОВАНИЕ.